18
Check whether there are leaks and whether a vacuum state has been achieved.
19
Start an anode refresh.
20
Measure the voltage at the membrane cell and monitor whether the voltage is not above
5 V DC per chamber.
21
Measure and check during production that the amperage is identical to the current
measured and shown on the control panel.
Maintenance checks and preparation for maintenance
62