11.7.6 Replacing the O-rings on the Bleed Valve
A2002
1.
Fig. 80: O-rings on the bleed valve
1.
Loosen the threaded connector (1) on the bleed valve.
2.
Dismantle the connector cap on the bleed valve.
3.
Replace the O-rings on the bleed valve
4.
Replace the bleed valve.
5.
Fit the bleed valve.
11.8 Maintenance on the product tank
n
User qualification, maintenance: trained user
‘User qualification’ on page 10
11.8.1 Prerequisites for maintenance
WARNING!
Danger due to product residue
Possible consequence: Fatal or very serious inju‐
ries from product residue.
Measure: Wear the goggles and gloves provided
during maintenance on the product tank.
Ventilate the room during maintenance.
INFORMATION!: The standard scope of delivery includes the level
switch. The product tank, the dry-running level switch and the
product suction unit are optional. This maintenance manual
describes the maintenance of the level switch and the product suc‐
tion unit. The maintenance package consists of materials for main‐
taining these components.
11.8.2 Checking for leak-tightness
Check the product tank for leak-tightness.
Annual maintenance:
Three-yearly maintenance:
The maintenance package
Preventative maintenance