11.7.3 Replacing the Refresh Valve
A1997
1.
Fig. 77: Refresh valve (1)
1.
Loosen the threaded connectors on the refresh valve (1).
2.
Remove the connector cap from the refresh valve.
3.
Replace the O-rings.
4.
Replace the refresh valve and O-rings.
5.
Fit the connector cap on the refresh valve.
11.7.4 Replace the O-rings on the Refresh Tap
A1998
1.
Fig. 78: O-rings on the refresh tap (1)
1.
Replace the O-rings.
2.
Replace the refresh tap and O-rings.