11.3.2 Cleaning the Suction Unit in the Brine Storage Tank
A1968
1.
2.
3.
4.
5.
6.
Fig. 47: Cleaning the suction unit in the brine storage tank
1.
Unscrew the coupling on both hoses (1) on the suction unit.
2.
Remove the suction unit (2) out of its housing.
3.
Unscrew the filter meshes (3) from the housing.
4.
Flush the filter meshes (4) with softened water.
Replace the filter meshes during three-yearly maintenance.
5.
Screw the clean / new filter meshes into the housing.
6.
Remove the non-return valve (5).
7.
Flush the non-return valve (5) with softened water.
8.
Make sure that the arrow on the non-return
valve points upwards.
Remove the non-return valve (5)
9.
Make sure that the arrow on the non-return
valve points upwards.
Make sure that there are O-rings in the cou‐
pling and that they are undamaged.
Insert the suction units into the housing.
10. Screw the coupling on both hoses onto the suction unit.
Performing maintenance on both suc‐
tion lines:
Preventative maintenance
73
Summary of Contents for Chlorinsitu-III
Page 18: ...A1706 15 4 13 3 3 16 12 17 Fig 8 Components of the system side B Components of the system 18 ...
Page 117: ...117 ...
Page 118: ...118 ...
Page 119: ...119 ...