N7000 STD ASCII Printers Fault Messages
181
B35 STATUS:
WAITING FOR EC
STATUS
N/A
Status message: the DC
on the controller board is
waiting for
communication with the
EC. If this message does
not clear witin a few
seconds there is an
electrical or electronic
problem on the controller
board.
Cycle power to see if the message
clears, if not, contact your
authorized service representative.
1
B40 ERROR: SDRAM
EEPROM CKSUM
BAD*
No
Flash memory has not
passed boot initialization
tests.
Cycle power to see if the message
clears, if not, contact your
authorized service representative.
1
B41 ERROR: DIM
MEMORY NOT
SDRAM*
No
The DRAM DIMM
installed on the controller
board is not Synchronous
DRAM (SDRAM).
Cycle power to see if the message
clears, if not, contact your
authorized service representative.
1
B42 ERROR: SDRAM
ROWS NOT
ALLOWED*
No
Printer boot initialization
tests detect incorrect
SDRAM.
Cycle power to see if the message
clears, if not, contact your
authorized service representative.
1
B43 ERROR: SDRAM
TOO MANY BANKS*
No
Printer boot initialization
tests detect incorrect
SDRAM.
Cycle power to see if the message
clears, if not, contact your
authorized service representative.
1
B44 ERROR: SDRAM
NOT 64 BITS WIDE*
No
Printer boot initialization
tests detect incorrect
SDRAM.
Cycle power to see if the message
clears, if not, contact your
authorized service representative.
1
B45 ERROR: SDRAM
IS WRONG VOLTAGE*
No
Printer boot initialization
tests detect incorrect
SDRAM.
Cycle power to see if the message
clears, if not, contact your
authorized service representative.
1
B46 ERROR: SDRAM
HAS MIXED SIZES*
No
Printer boot initialization
tests detect incorrect
SDRAM.
Cycle power to see if the message
clears, if not, contact your
authorized service representative.
1
B47 ERROR: SDRAM
LARGER THAN 256M*
No
Printer boot initialization
tests detect incorrect
SDRAM.
Cycle power to see if the message
clears, if not, contact your
authorized service representative.
1
B49 ERROR: SDRAM
# LOGICAL BANKS*
No
Printer boot initialization
tests detect incorrect
SDRAM.
Cycle power to see if the message
clears, if not, contact your
authorized service representative.
1
B50 ERROR: SDRAM
LOGIC COMB BANKS*
No
SDRAM DIMM is not
compatible with the
computer. SDRAM DIMM
may not be properly
installed.
Cycle power to see if the message
clears, if not, contact your
authorized service representative.
1
Table 12. N7000 STD ASCII LCD Fault Messages Troubleshooting
Displayed Message
Can User
Correct?
Explanation
Solution
Summary of Contents for N7000 H-Series
Page 1: ...N7000 and N7000 H Series Cartridge Ribbon Printer User s Manual...
Page 3: ...User s Manual N7000 and N7000 H Series Cartridge Ribbon Printers...
Page 20: ...20 Chapter 2 Printer Component Locations...
Page 44: ...44 Chapter 3 Integrated Print Management System...
Page 238: ...238 Chapter 7 Diagnosing Problems...
Page 244: ...244 Appendix A Printing Rates...
Page 246: ...246 Appendix B...
Page 258: ...258 Appendix C Performance Limitations...
Page 291: ......
Page 292: ...256169 001C 256169 001...