171
6
Reprogramming the
Security Key
Reprogramming the Security Key
The security key on the PSA3 controller board can be reprogrammed with a
Software Program Exchange (SPX) module. The SPX is an intelligent module
that plugs into the debug port on the back of printers equipped with the PSA3
“Hurricane” controller board. The SPX is used only once; it automatically
overwrites itself after successfully reprogramming a security key. This allows
the end user or a service technician to enable features such as new
emulations without having to remove covers and install a new security key on
the controller board.
The SPX is used at power-up only and is not left in the printer during normal
operation. Because it is a single-use disposable item the user is not required
to return it to the vendor or manufacturer.
How to Program the Security Key
1.
Power off the printer.
2.
On cabinet models, open the rear door. On pedestal models, refer to
Figure 24 to locate the debug port at the rear of the printer.
3.
Insert the SPX into the debug port as shown.