RealPresence Collaboration Server (RMX) 800s/Virtual Edition Administrator’s Guide
Polycom®, Inc.
647
Deleting a Flag
To delete a flag:
1
In the
System Flags
dialog box, select the flag to delete and click the
Delete Flag
button.
2
In the confirmation message box, click
Yes
to confirm.
3
Click
OK to
close the
System Flags
dialog box.
Auto Layout Configuration
The
Auto Layout
option lets the Collaboration Server automatically select the conference video layout
based on the number of participants currently connected to the conference. You can modify the default
selection of the conference video layout to customize it to your conferencing preferences.
Customizing the Default Auto Layout
The default
Auto Layout
is controlled by 13 flags:
PREDEFINED_AUTO_LAYOUT_0,
... ,
PREDEFINED_AUTO_LAYOUT_12
Each of the 11
Auto Layout
flags can be left at its default value, or set to any of the
Possible Values
listed
in the following
Default Auto Layouts
table.
The flag that controls the
Auto Layout
you wish to modify must be added to the
System Configuration
file. For more information see
Modifying System Flags
.
SIP_TCP_TLS_TIMER
S
Determines the timeout characteristics of SIP TCP TLS connections.
Format: SIP_TCP_TLS_TIMERS = <string>
The string contains the following parameters:
Ct - Timeout of
TCP CONNECT
operation (seconds)
Cs - Timeout of
TLS CONNECT
operation (seconds)
A - Timeout of
accept
operation (seconds)
D - Timeout of
disconnect
operation (nanoseconds)
H - Timeout of
handshake
operation (seconds)
Default: <1,5, 4,500000,5>
SIP_TIMERS_SET_IND
EX
SIP Timer type timeout settings according to standard or proprietary protocol.
Possible values are:
0 - Default
1 - SIP Standard recommendation.
Note:
For homologation and certification testing, this flag must be set to 1.
SIP_TO_TAG_CONFLI
CT
For use in Microsoft environments.
In case of forking, a tag conflict will be resolved when Status 200 OK is received from an
answering UA.
Default: YES
Manually Added CS_MODULE_PARAMETERS System Flags
Flag
Description