RealPresence Collaboration Server (RMX) 800s/Virtual Edition Administrator’s Guide
Polycom®, Inc.
374
To detect the disconnection of SIP endpoints in a reasonable amount of time, a new system flag can be
defined to specify the amount of time that the MCU should wait for an RTCP or RTP message from the SIP
endpoint before the endpoint starts the disconnection process. The system default value is automatically
set to 20 seconds.
The system flag, DETECT_SIP_EP_DISCONNECT _TIMER, contains the amount of time in seconds to
wait for an RTCP or RTP message to be received from the endpoint. When the time that was set in the
system flag has elapsed and no RTCP or RTP audio or video message has been received on either the
audio or the video channel, the MCU disconnects the SIP endpoint from the conference. A CDR event
record is created with a Call Disconnection Cause of “SIP remote stopped responding”.
The Microsoft Lync add-in endpoint opens audio and content channels. Lync endpoints can send
RTCP/RTP messages and empty RTP audio messages. When the time that was set in the system flag has
elapsed and no RTCP or RTP message has been received on the audio channel, the MCU disconnects the
endpoint from the conference.
SIP audio only endpoints use the audio channel only. When the time that was set in the system flag has
elapsed and no RTCP or RTP message has been received on the audio channel, the MCU disconnects the
SIP audio endpoint from the conference.
Configuring the System Flag
When you want to change the system default value of 20 seconds, the system flag,
DETECT_SIP_EP_DISCONNECT_TIMER, can be manually added to the
System Flags
configuration to
detect the disconnection of SIP endpoints. For more information see
Manually Adding and Deleting System
Flags
.
The value range is from 0 to 300 seconds. When the value is set between 0 and 14, the feature is disabled
and SIP endpoints are not detected for disconnection. When the value is set between 15 and 300, the
feature is enabled.
Monitoring Telepresence Participant Properties
A
Telepresence
status indicator is displayed in the
Participant
Properties - Advanced
tab when monitoring
conference participants.