perma PRO C
- 1 -
99
Outlets
1
3
2
4
5
6
Days
Weeks
Months
%Vol.
LC250
0
Config.
Time
PIN
Lubrication System perma PRO C
Display
Confi guration menu
For entering the settings
.
Outlets 1 - 6
Shows activated outlets
Number
Shows remaining volume,
discharge period, outlet no.,
PIN, and malfunction codes.
Setting Mode
Displays the current setting in
days, weeks, or months.
Size of PRO LC unit
Displays volume of LC unit
(250 or 500 cm
3
)
Ice icon
Indicates either that the temperature
fell below 0 °C/32 °F (icon blinking),
or that the low temperature shutoff
(below -20 °C/-4 °F) has turned the
system off (icon permanent).
Remaining volume
of the PRO LC unit
Shows the lubricant
remaining in the PRO
LC unit in % volume.
Protection cover
With bayonet catch for
quick opening/closing.
PRO LC unit
(Lubrication Canister)
Cartridge, piston, spindle
fi lled with lubricant.
Red LED
Additional malfunction
indication.
Push Button: MODE/SAVE
Leads to the Confi guration Menu
and saves the selected settings.
Drive Unit
Contains electronics,
motor and pump system.
Connector
Used for plugging in the
connecting cable which connects
the perma PRO C with the control
system (e.g. of a PLC).
Content
Description of the fi lling date and the
contained lubricant.
Type
Product type and size of
PRO LC unit.
Display
Informs about operating conditions,
malfunctions, settings and the
lubricant volume left in the
PRO LC unit.
Green LED
Additional indication of the current
operating condition.
Push Button SELECT
To change settings.
Connection f. distributor
PRO MP-6
Connection thread
G3/8 for screwing into a lubrication
point or for connecting a lubricant
tube.
Drive Unit
Interlocking teeth
to position the
PRO LC unit
No function!
Setting of PRO LC unit
size is done via menu on the display.
Catch
for driving the spindle.
Connecting Cable
1
2
4
3
1
2
4
3
Pin-number
Strand color
Function
1
brown
Not assigned
2
white
Malfunction
3
blue
Ground
4
black
Voltage
Pin assignment
of the connector
Pin assignment
of cable connector
Connecting cable
For connecting the
lubricator to the
control system.
Summary of Contents for Distributor PRO MP-6
Page 3: ...Chap 4 3 perma PRO MP 6 Distributor Drilling template...
Page 4: ...45 75 66 5 6 5 Drilling template Screws M6 2x Fasting points 3x Fasting points...
Page 77: ...Chap 4 3 perma PRO MP 6 Distributor Drilling template...
Page 78: ...45 75 66 5 6 5 Drilling template Screws M6 2x Fasting points 3x Fasting points...