perma PRO MP-6 Distributor
- 9 -
351,5 (for lubricators with PRO LC 250) 402,5 (for lubricators with PRO LC 500)
75
45
4.3
Combination of Distributor and Lubricator
After you have equipped the perma MP-6 with connections, you can connect the distributor to a lubricator of the
PRO range.
Screw the distributor and the lubricator together. Attach both to the perma mounting device and install
the mounting device.
Direct Mounting of the Distributor onto the Lubricator
♦ Before you connect the distributor and the lubricator, all lubrication points must be pre-greased and all grease
lines must be pre-fi lled with the same lubricant that the PRO LC unit contains. For that, perma-tec offers a
400 g lubrication cartridge for manually-operated grease presses with the requested lubricant.
♦ Screw the lubricator tightly into the G3/8 thread of the distributor.
♦ Position the rear sides of the lubricator and the distributor at one level.
♦ Attach the supplied mounting device to the distributor and the lubricator using the enclosed hex head bolts
(M6 x 16) and the washers.
♦ Screw the mounting device together with the lubrication system onto a support of your system.
For the position of the bores of the four fi xing screws refer to fi gure 6 below. You have to use four hexagon
screws M6 x 25 (e.g. on metal ground).
♦ Connect the grease lines to the connections of the distributor and install the tubes correctly between the
distributor and the lubrication point. Tube length may not exceed fi ve meters per outlet.
♦ Attach the required connections to the ends of the lubricant tubes.
♦ While the lubrication system is
switched off
connect the lubricator to the distributor with the connecting cable.
♦ The lubrication system is now ready for operation.
Ensure correct and tight assembly of the connections and grease lines to avoid possible leakage.
fi gure 6
2 hex head bolts M6 x 16,
maximum torque 3 Nm
(for attaching the lubricator to the
mounting device)
2 hexagon screws
M6 x 25 (for wall
mounting on metall)
2 hex head bolts M6 x 16,
maximum torque 3 Nm
(for attaching the distributor to
the mounting device)
2 hexagon screws
M6 x 25 (for wall
mounting on metal)
Summary of Contents for Distributor PRO MP-6
Page 3: ...Chap 4 3 perma PRO MP 6 Distributor Drilling template...
Page 4: ...45 75 66 5 6 5 Drilling template Screws M6 2x Fasting points 3x Fasting points...
Page 77: ...Chap 4 3 perma PRO MP 6 Distributor Drilling template...
Page 78: ...45 75 66 5 6 5 Drilling template Screws M6 2x Fasting points 3x Fasting points...