perma PRO C
- 14 -
6.7
Determining the Discharge Period Without Impulse Mode
The discharge period is automatically factory-set to six months according to the supplied PRO LC unit.
Upon request, a factory-setting of the discharge period required by the customer is also possible. The size of
the PRO LC unit is taken into account.
If you want to determine the discharge period, you need to know the required amount of the lubricant in cubic
centimeters for 100 operating hours (cm
3
/100 h). This information can be taken from the technical documents of
the manufacturer of the lubrication point. With this information, you can determine the discharge period using the
following chart (chart 5).
Please take into account that in case of one or several additional discharges, the remaining discharge period
of the lubrication system must be recalculated (refer to chapter 6.9). This also applies in case of a cut-off of the
lubrication system due to a long machine standstill (e.g. weekends or annual holidays). You should also note the
result of your calculation of the remaining discharge period in your lubrication and maintenance schedule.
The perma SELECT software helps you to determine the discharge period.
Visit our website www.perma-tec.com for a free download of this software.
Average discharge volume in cm
3
per 100 operating hours
PRO LC unit
250
500
Days
Weeks
Months
Days
Weeks
Months
1
1041.7
148.8
34.3
2083.3
297.6
68.5
2
520.8
74.4
17.1
1041.7
148.8
34.3
3
347.2
49.6
11.4
694.4
99.2
22.8
4
260.4
37.2
8.6
520.8
74.4
17.1
5
208.3
29.8
6.9
416.7
59.5
13.7
6
173.6
24.8
5.7
347.2
49.6
11.4
7
148.8
21.3
4.9
297.6
42.5
9.8
8
130.2
18.6
4.3
260.4
37.2
8.6
9
115.7
16.5
3.8
231.5
33.1
7.6
10
104.2
14.9
3.4
208.3
29.8
6.9
11
94.7
13.5
3.1
189.4
27.1
6.2
12
86.8
12.4
2.9
173.6
24.8
5.7
13
80.1
11.4
2.6
160.3
22.9
5.3
14
74.4
10.6
2.4
148.8
21.3
4.9
15
69.4
9.9
2.3
138.9
19.8
4.6
16
65.1
9.3
2.1
130.2
18.6
4.3
17
61.3
8.8
2.0
122.5
17.5
4.0
18
57.9
8.3
1.9
115.7
16.5
3.8
19
54.8
7.8
1.8
109.6
15.7
3.6
20
52.1
7.4
1.7
104.2
14.9
3.4
21
49.6
7.1
1.6
99.2
14.2
3.3
22
47.3
6.8
1.6
94.7
13.5
3.1
23
45.3
6.5
1.5
90.6
12.9
3.0
24
43.4
6.2
1.4
86.8
12.4
2.8
25
41.7
--
--
83.3
--
--
26
40.1
--
--
80.1
--
--
27
38.6
--
--
77.2
--
--
28
37.2
--
--
74.4
--
--
29
35.9
--
--
71.8
--
--
30
34.7
--
--
69.4
--
--
chart 5
Setting Mode
Setting point
discharge period
Summary of Contents for Distributor PRO MP-6
Page 3: ...Chap 4 3 perma PRO MP 6 Distributor Drilling template...
Page 4: ...45 75 66 5 6 5 Drilling template Screws M6 2x Fasting points 3x Fasting points...
Page 77: ...Chap 4 3 perma PRO MP 6 Distributor Drilling template...
Page 78: ...45 75 66 5 6 5 Drilling template Screws M6 2x Fasting points 3x Fasting points...