perma PRO MP-6 Distributor
- 2 -
Quick Reference Guide for the Distributor perma MP-6
On this page you will find some important information for quick and easy operation and setting of your perma MP-6 dis-
tributor. Before the perma MP-6 is used, prior to the assembly of the distributor with a lubricator of the perma PRO range
and whenever you need detailed information, you should read the complete Operating Instructions, which contain infor-
mation that must be observed. Make sure to follow the instructions given in the chapter “Safety Instructions”.
Additionally, you have to observe the Operating Instructions of the connected lubricator.
1
Assembly of perma MP-6
(refer to chapter 4.1 and 4.2)
♦ Screw connections into the outlets that you want to activate and seal the other outlets with plugs.
2
Connect perma MP-6 to the Lubricator
(refer to chapter 4.3)
♦ Screw the lubricator tightly into the thread of the distributor.
♦ Position the rear sides of the lubricator and the distributor at one level.
♦ Attach the distributor and the lubricator to the mounting device and fix it using the four bores (refer to figure 6).
♦ Connect the lubricant tubes (Ø 8 x 1.5, inner-Ø 5 mm, admissible total length per pipe up to 5 m) to the
connecting pieces of the distributor and lay them between the distributor and the lubrication point.
♦ Connect the lubricator with the distributor using the connecting cable. For this, the lubrication system must
be switched off.
3
Determine Discharge Period
(refer to chapter 5.7)
♦ Determine the required lubricant volume (cm
3
) per one hundred operating hours while taking into account the
number of open outlets. For this, you have to multiply the lubricant volume with the number of open outlets.
♦ You have to take into account that this distributor is able to supply an equal amount of lubricant to up to six
lubrication points.
♦ Determine the required discharge volume using the Operating Instructions of the lubricator. Depending on the
size of the PRO LC unit you can then determine the setting of the discharge period and the setting mode.
♦ You may also refer to our perma SELECT program which can be downloaded from our web page free of
charge. It helps you in selecting the correct settings.
4
Setting and Starting the Complete Lubrication System
(refer to chapter 5.5)
♦ Set discharge period or impulse mode, size of PRO LC unit, outlets, PIN (refer to PRO/PRO C operating
instructions, chapter 6.8, of each lubricator).
♦ Keep the ON/OFF/SELECT button of the lubricator
PRO
pressed until the display no longer shows “ ”
(for Off).
To start the lubrication system
PRO C
switch on power supply.
♦ An automatic initialization is carried out by the lubrication system and the display shows the counting of the
outlets.
♦ After the initialization is complete, the display of the lubricator shows the remaining volume and the lubri-
cation system starts to operate.
Summary of Contents for Distributor PRO MP-6
Page 3: ...Chap 4 3 perma PRO MP 6 Distributor Drilling template...
Page 4: ...45 75 66 5 6 5 Drilling template Screws M6 2x Fasting points 3x Fasting points...
Page 77: ...Chap 4 3 perma PRO MP 6 Distributor Drilling template...
Page 78: ...45 75 66 5 6 5 Drilling template Screws M6 2x Fasting points 3x Fasting points...