perma PRO
- 16 -
Caption for Chart on Left Side
Instructions should be followed from top to bottom and from left to right (also refer to chart 3). The instructions
correspond to the operating sequence on the turned-off lubrication system perma PRO. Configuration is also
possible if perma PRO is On.
chart 6
Function
short push
long push
blinking display
go to
Symbol
CONFIGURATION SECTIONS (see vertical bar, chart 5)
I N T R O
INTRO informs
Info
and asks for the current PIN.
PIN Entry
C O N F I G U R A T I O N M E N U E
Settings can be changed in the configuration menu with its different sections (LC, Time, Outlets, PIN).
LC
You can change the PRO LC unit size from LC250 to LC500 and back by pushing the ON/OFF/SELECT button
(refer to chapter 7.1 and 7.2).
Time
The discharge period can only be set in
one
type of calendar unit (i.e. either Months, Weeks or Days). When
the highest unit size is reached, counting starts again with number “ ”.
Outlets
If a MP-6 distributor is connected, outlets 1 - 6 can be set individually. The activated outlets 1 - 6 are displayed
with a filled-in square in the display (please refer to the operating instruction of the MP-6 distributor for more
details).
PIN
We strongly suggest to enter a personal PIN in order to protect your settings from unauthorized access. The
PIN can
only be changed during initial configuration or after a PIN-reset
. A PIN-reset (short push of but-
tons: left-left-right-right-left in the INTRO-Info-menu) changes your personal PIN back to “ ”. The PIN-reset
was successful when the displayed time disappears for a second and then comes back on. All other settings
remain unchanged.
Save or Reject Changed Settings
The display settings can be saved with a long push of the MODE/SAVE button. If you do
not
want to save your
changes to settings that are currently displayed in the configuration menu (LC, Time, Outlets, PIN), press the
ON/OFF/SELECT button until the display shows either (“ ”) for Off or the remaining volume of the PRO LC unit
in % VOL. All other settings and already saved changes remain valid.
Automatic Termination of the Configuration Mode
If you do not press a button in the configuration menu for 180 seconds, the control system is automatically
switching back to the previously set mode (“On” or “Off”) without saving the changes. All other settings and
already saved changes remain valid.
Additional Discharge
With an additional discharge, a lubrication point can be supplied with an additional amount of the lubricant.
For an additional discharge, the lubrication system must be switched on (display shows remaining volume) and
you have to press both buttons simultaneously and hold them down (refer to figure 15).
figure 15
Lubricator On
For an additional discharge, press both buttons at the
same time and hold them down (> 4 sec.)
An additional discharge is only possible at temperatures above 0 °C / 32 °F (figure 16, ice crystal is not visible)
and when the lubrication system is not currently conducting a regular discharge.
Every additional discharge reduces the remaining discharge period since an increased amount of the lubricant
has been supplied. This must be taken into account in your lubrication and maintenance schedule. A calculation
is possible with the formula from chapter 6.9 and with the remaining volume which is displayed.
The time between two additional discharges is 30 seconds. Each additional long push of both buttons
(simultaneously, figure 15) during this time is being registered and will lead to even more additional
discharges. The system remembers a max. of 5 additional discharges.
MODE
SAVE
ON/OFF
SELECT
%Vol.
LC 500
Summary of Contents for Distributor PRO MP-6
Page 3: ...Chap 4 3 perma PRO MP 6 Distributor Drilling template...
Page 4: ...45 75 66 5 6 5 Drilling template Screws M6 2x Fasting points 3x Fasting points...
Page 77: ...Chap 4 3 perma PRO MP 6 Distributor Drilling template...
Page 78: ...45 75 66 5 6 5 Drilling template Screws M6 2x Fasting points 3x Fasting points...