General information
perma PRO / PRO C LINE is based on the function of perma PRO / PRO C LINE.
The general function of perma PRO / PRO C has not been changed.
These perma PRO / PRO C LINE Operating Instructions must always be used together with the Operating
Instructions of perma PRO / PRO C.
Function Indication on the Display
(see operating instructions perma PRO / PRO C chapter 5.2)
Lubrication system turned off (OFF)
Lubrication system turned on (ON)
Differences perma PRO / PRO C LINE (compared to perma PRO / PRO C)
The pause time between two discharges and the discharge amounts from 1 to 9 strokes can be programmed
for each individual outlet
.
After each pause time, the system will conduct a discharge with as many strokes as programmed for this outlet.
The following settings and displays are new
(operating instructions perma PRO / PRO C chapter 6.8):
♦ Number of strokes per discharge (1 stroke = 0.5 cm
3
)
♦ Pause time in days between discharges
♦ Display of discharge time remaining
The chart on the following page will assist with settings.
Total discharge period
The longest discharge period that the system can be programmed for is
24 months
(in order to stay within the
maximum lubricant service life).
The system calculates the total discharge period based on the number of strokes programmed and the pause
time for each outlet. The system performs this calculation when the user enters and saves the pause time. If,
at this time, the system recognises that the max. discharge period of 24 months will be exceeded, the display
shows error for about 3 seconds. Then the system will return to the last configuration step = programmed
strokes per discharge for the outlet that was programmed last. The user must now either increase the lubricant
amount or reduce the pause time.
88
Outlets
1
3
2
4
5
6
Days
Weeks
Months
%Vol.
LC250
0
LC
2
500
Confi g.
Time
Time
PIN
88
Outlets
1
3
2
4
5
6
Days
Weeks
Months
%Vol.
LC250
0
LC
2
500
Confi g.
Time
Time
PIN
Time
Outlets
1
3
2
4
5
6
Weeks
LC 500
Translation of the Original Operating Instructions
perma PRO / PRO LINE C 250 / 500
Display shows „remaining
discharge period“
Summary of Contents for Distributor PRO MP-6
Page 3: ...Chap 4 3 perma PRO MP 6 Distributor Drilling template...
Page 4: ...45 75 66 5 6 5 Drilling template Screws M6 2x Fasting points 3x Fasting points...
Page 77: ...Chap 4 3 perma PRO MP 6 Distributor Drilling template...
Page 78: ...45 75 66 5 6 5 Drilling template Screws M6 2x Fasting points 3x Fasting points...