perma PRO
- 2 -
Quick Reference Guide for the Lubrication System perma PRO
On this page you will find some important information for quick and easy operation and setting of the perma PRO.
Before the first installation of the perma PRO, and whenever you need detailed instructions, you should read the
complete Operating Manual which contains information that must be observed. Make sure to follow the instructions
given in the chapter “Safety Notes”.
1
Assembly of perma PRO / Exchange of PRO LC unit
(refer to chapter 4 and 7)
♦ Mount the drive unit on the mounting plate and secure it at the three pre-drilled holes (see attached
template).
♦ Insert a new battery set into the battery compartment (follow directions of the arrows).
♦ Place the PRO LC unit inside the cover and remove the plug of the PRO LC unit.
♦ Push the PRO LC unit into the cover until lubricant comes out of the opening.
♦ Place the PRO LC unit with its cover on the drive-unit. Make sure that the catch locks and that the
teeth of PRO LC unit and drive unit interlock.
♦ Turn the cover clockwise until the bayonet catch locks.
2
Determine Discharge Period
(refer to chapter 6.7)
♦ Refer to the manufacturer’s guidelines about the lubrication point that you want to lubricate, in order
to determine the required lubricant amount in cm
3
per one hundred operating hours.
♦ Refer to chart 3 (chapter 6.7, chart 4) and find your required lubrication amount. Based on that,
the chart will show you the required PRO LC unit size, the setting of the discharge period, and
the setting mode.
♦ You may also refer to our perma Select program which can be downloaded from our web page free
of charge. It helps you in selecting the correct settings.
3
Setting of LC unit Size, Discharge Period, Outlets and PIN
(refer to chapter 6.8)
♦ Hold down the MODE/SAVE button until the set time is displayed.
♦ Hold down the MODE/SAVE button again until you reach the current PIN (PIN cannot be changed
here/PIN setting at delivery is “ ”).
♦ Hold down the MODE/SAVE button again until you reach the other setting menus:
LC unit, discharge period, outlets (only with attached MP-6), and PIN change. Change settings with
a short push of MODE/SAVE or ON/OFF/SELECT.
4
Save Settings
(refer to chapter 6.8)
♦ Keep the MODE/SAVE button pressed until display shows “ ”.
5
Starting perma PRO
(refer to chapter 6.5)
♦ Hold down the ON/OFF/SELECT button until the “Remaining Volume” appears in the display and
the green LED starts blinking.
6
Stopping perma PRO
(refer to chapter 6.6)
♦ Keep the ON/OFF/SELECT button pressed until the display shows “ ”.
Summary of Contents for Distributor PRO MP-6
Page 3: ...Chap 4 3 perma PRO MP 6 Distributor Drilling template...
Page 4: ...45 75 66 5 6 5 Drilling template Screws M6 2x Fasting points 3x Fasting points...
Page 77: ...Chap 4 3 perma PRO MP 6 Distributor Drilling template...
Page 78: ...45 75 66 5 6 5 Drilling template Screws M6 2x Fasting points 3x Fasting points...