perma PRO C
- 11 -
%Vol.
LC 500
5.
Display and Control Elements of the Lubrication System
5.1
Display Elements
The operating status of the lubricator can be determined via the green or the red LED and via the display at the
control unit (refer to figure 8) of the perma PRO C.
The perma PRO C offers a menu-guided setting. Changes of the settings are shown on the display. Error
messages, e.g. in case the pressure in the lubricant tube gets too high, are also indicated on the display.
5.2
Function Indication on the Display
The display is located on the control unit of the perma PRO C (refer to figure 8, chapter 5.1).
The display shows settings, operating conditions and error messages of the lubricator.
In case of an error free operation of the lubrication system, the display shows the remaining volume of the
mounted PRO LC unit in percent volume (% Vol.). Figure 9 shows an example of the displayed information
if the PRO LC unit 500 is new and full.
figure 8
MODE
SAVE
push-button
LCD
red LED
SELECT
push-button
green LED
Connector for
distributor MP-6
The display cannot be switched off by the operator. If the lubrication system is switched off, the display
will always show two lines (see figure 10 below).
figure 9
figure 10
5.3
Function Indication via the LEDs
LED
Signal
Signal Length
Explanation
green
flash
every 10 seconds
operation (OK)
red
flash
every 3 seconds
error / malfunction
green and red
flash
every 3 seconds
PRO LC unit empty
green
light
permanently
Lubricator is discharging
chart 3
5.4
Function Indication via the Connected Control System
The connected control system of your equipment can only indicate that the lubricator is working, or that there is
a malfunction. If the perma PRO C is working, the control system receives a “High” signal and for a malfunction a
“Low” signal.
Summary of Contents for Distributor PRO MP-6
Page 3: ...Chap 4 3 perma PRO MP 6 Distributor Drilling template...
Page 4: ...45 75 66 5 6 5 Drilling template Screws M6 2x Fasting points 3x Fasting points...
Page 77: ...Chap 4 3 perma PRO MP 6 Distributor Drilling template...
Page 78: ...45 75 66 5 6 5 Drilling template Screws M6 2x Fasting points 3x Fasting points...