perma PRO
- 13 -
6.3
Setting into Operation
♦ If necessary, mount the drive unit onto a fixing device for wall-mounting (refer to chapter 4.1).
♦ Insert the battery set into the drive unit and the PRO LC unit into the protection cover and close the complete
system (refer to chapter 4.2 b - d).
♦ Determine the discharge period (refer to chapter 6.7).
♦ Set volume of PRO LC unit, discharge period, outlets of MP-6, and the PIN via buttons on display (refer to
chapter 6.8).
♦ Switch-on the lubrication system (refer to chapter 6.5).
♦ Carry out an additional discharge (refer to chapter 6.8).
If the drive motor has started and the green LED is lit, the lubricator has started to discharge. The display
indicates the remaining volume (% Vol.) of the PRO LC unit.
The operator must always check the customer-specific settings and if necessary change them before the
lubricator is set into operation!
6.4
During Operation
♦ Carry out regular inspections during the operation. You should pay special attention with regard to leakage
and to the condition of the lubricator!
♦ Check the condition of the lubricant tube and the connections regularly!
♦ Check the filling level of the transparent PRO LC unit regularly!
♦ After one or several additional discharges, you have to calculate the reduced discharge period and note this
on your lubrication and maintenance schedule.
♦ If a malfunction is indicated on the display, you can determine the cause using the trouble shooting guide
(refer to chart 7, chapter 8.2). If the fault cannot be fixed, please contact your supplier for technical support.
Additional discharges and long machine standstills must always be taken into account with regard to the
remaining discharge period of the lubricator.
6.5
Switching the Lubrication System On
To switch the lubrication system on (refer to figure 13), keep the ON/OFF/SELECT button pressed until the
indication (“ ”) on the display is replaced by an indication of the remaining volume – e.g. % VOL (with a
new PRO LC unit) – and the green LED starts blinking.
6.6
Switching the Lubrication System Off
To switch the lubrication system off (refer to figure 14), keep the ON/OFF/SELECT button pressed until the
display no longer indicates the remaining volume – % VOL – but indicates (“ ”) instead. When the lubrication
system is switched off, all of the settings are saved. This means that if you start the lubricator again, it will take
up the operation at the point where it had been switched off.
ON/OFF
SELECT
%Vol.
LC 500
figure 13
ON/OFF
SELECT
%Vol.
LC 500
figure 14
Summary of Contents for Distributor PRO MP-6
Page 3: ...Chap 4 3 perma PRO MP 6 Distributor Drilling template...
Page 4: ...45 75 66 5 6 5 Drilling template Screws M6 2x Fasting points 3x Fasting points...
Page 77: ...Chap 4 3 perma PRO MP 6 Distributor Drilling template...
Page 78: ...45 75 66 5 6 5 Drilling template Screws M6 2x Fasting points 3x Fasting points...