background image

 

 

 

Fieldbus Independent 
I/O Modules 

SSI Transmitter Interface 
750-630 

Manual 

 

 
Version 1.0.2 

Summary of Contents for 750-630

Page 1: ...Fieldbus Independent I O Modules SSI Transmitter Interface 750 630 Manual Version 1 0 2...

Page 2: ...571 8 87 5 55 Fax 49 0 571 8 87 85 55 E Mail support wago com Every conceivable measure has been taken to ensure the correctness and com pleteness of this documentation However as errors can never be...

Page 3: ...1 2 Symbols 5 1 3 Number Notation 5 1 4 Safety Notes 6 1 5 Scope 6 2 I O Modules 7 2 1 Special Modules 7 2 1 1 750 630 xxx xxx SSI Transmitter Interface 7 2 1 1 1 Variations 7 2 1 1 2 View 7 2 1 1 3...

Page 4: ...ufacturers are always named without referring to patent rights The existence of such rights can therefore not be ruled out 1 1 2 Personnel Qualification The use of the product detailed in this manual...

Page 5: ...ation ESD Electrostatic Discharge Warning of damage to the components by electrostatic discharge Observe the precautionary measure for handling components at risk Note Routines or advice for efficient...

Page 6: ...nformation is to be regarded Do not use any contact spray The spray may impair the functioning of the contact area The WAGO I O SYSTEM 750 and its components are an open system It must only be assembl...

Page 7: ...Status SSI Transmitter Interface 750 630 000 006 SSI 24Bit 250kHz Gray SSI Transmitter Interface 750 630 000 007 SSI 24Bit 83kHz Gray Status SSI Transmitter Interface 750 630 000 008 SSI 25Bit 125kHz...

Page 8: ...field side supply voltage of 24 V for the output module is derived from adjacent I O modules or from a supply module The supply voltage for the field side is made automatically through the individual...

Page 9: ...if no process data is transmitted by the fieldbus coupler controller for 100 ms 13 14 C D B A A Fig 2 1 1 1 Display Elements g063002x A green Status on Normal operation 2 1 1 5 Schematic Diagram Statu...

Page 10: ...n Internal bit width 1 x 32 bits 24 bit used 8 bit reserved 2 x 8 bits control status option Isolation 500 V System Supply Dimensions W x H x L from upper edge of 35 DIN rail 12 mm x 64 mm x 100 mm We...

Page 11: ...means that accessing or parsing the status information depends on the fieldbus sys tem Attention The representation of the process data of some I O modules or their variations in the process image dep...

Page 12: ...ral error has occurred This bit is set in a FRAME or SSI IN error has occurred FRAME_E An invalid data frame has occurred i e the data frame is not terminated with zero possibly a wire breakage on clo...

Page 13: ...0 MHz 250 0kHz 125 0 kHz 100 0 kHz 83 0 kHz 71 0 kHz 62 5 kHz PI Length 0 Byte 24 Byte 32 Byte numeric input box Not used Variable data frame not active Var Frame Length 1 Byte 32 Byte Variable data f...

Page 14: ...dules Select box Available settings Disable Power fail bit not active Power Fail Bit Enable Power fail bit active default setting More Information Detailed Information about the parameterizing this mo...

Page 15: ...750 630 xxx xxx SSI Transmitter Interface 15 Adjustable Variation 750 630 003 000 WAGO I O SYSTEM 750 I O Modules...

Page 16: ...WAGO Kontakttechnik GmbH Co KG Postfach 2880 D 32385 Minden Hansastra e 27 D 32423 Minden Phone 05 71 8 87 0 Fax 05 71 8 87 1 69 E Mail info wago com Internet http www wago com...