ACCULINK 316x DSU/CSU
3-56
December 1996
3160-A2-GB22-10
Table 3-10
Self-Test Health Messages
Message
Description
Passed
No problems found during power-up.
CPU fail
Central Processing Unit failed internal testing.
DTE T1 fail
Unit failed to internally loop data on the DTE circuit.
Failure xxxxxxxx
An 8-digit hexadecimal failure code provided for service personnel.
LCD fail
The front panel Liquid Crystal Display (LCD) failed.
Memory fail
Unit failed program checksum verification.
Modem fail
Unit failed to internally loop data through the modem circuit.
NET T1 fail
Unit failed to internally loop data on the network circuit.
Device fail
One or more of the unit’s integrated circuit chips failed to pass internal device level testing.
B8ZS/LOS fail
Unit failed to encode data properly or to detect Loss Of Signal.
Alarm fail
Unit failed to transmit AIS or to detect Yellow alarm.
DSU fail
Unit failed to internally loop data on the DSU.
DSU Port
n fail
Port’s integrated circuit failed to pass device internal testing.
Unknown Exp Dev
Unit unable to recognize the expansion device connected to the main circuit board.
Displaying Self-Test Results
To display power-up self-test results,
1. Press F1 to select Stat from the top-level menu
screen.
F1
DSU ESF
Stat
Test
Cnfig
F2
F3
2. From the Status screen, press F2 to select STest.
F1
Status:
DevHS STest
Perf
F2
F3
3. View the results of the last power-up self-test. If
no problems were found during power-up, the
following message appears.
F1
STest Health:
Passed
F2
F3
Summary of Contents for ACCULINK 316x
Page 4: ...ACCULINK 316x DSU CSU C December 1996 3160 A2 GB22 10 Notices...
Page 23: ...Introduction 1 9 3160 A2 GB22 10 December 1996 Figure 1 6 Auxiliary Backplane...
Page 77: ...Operation 3 35 3160 A2 GB22 10 December 1996 Figure 3 24 Example Channel Allocation...
Page 135: ...A 1 3160 A2 GB22 10 December 1996 Front Panel Menu A...
Page 136: ...ACCULINK 316x DSU CSU A 2 December 1996 3160 A2 GB22 10...
Page 137: ...Front Panel Menu A 3 3160 A2 GB22 10 December 1996...