ACCULINK 316x DSU/CSU
2-12
December 1996
3160-A2-GB22-10
6. Enter the desired ID. Press F1 (Up) and F2
(Down) to scroll up and down through the valid
characters/numbers for the customer ID. Valid
characters are 0 through 9, #, -, ., /, A to Z, and
blank space. Press F3 (Save) to save the ID.
F1
CustID=xxxxxxxx
Up
Down
Save
F2
F3
Differences Using the Async Terminal: The customer
ID selection is found in the main/control/miscellaneous
control options menu. Select Customer Identification
Name/Number from that menu.
Establishing Access Security
on a Port
Although the password feature is available, it is not
required as a factory default. If used, it ensures access
security before device control is passed to a PC or
terminal connected to a port. The password configuration
option can be individually set for the COM or MODEM
port, or both if security is needed on both port types. The
default is none. From the front panel, set this
configuration option using the Control branch. Select
cnfig
→
edit
→
user
→
password. The password itself is set
separately. Refer to the section Setting/Changing a
Password.
Differences Using the Async Terminal: The password is
set in the main/configuration/edit/user screen. Figure 2-11
shows an example of this screen.
Customer ID: New Cust
main/configuration/edit/user
Model: ACCULINK XXXX
Save Edit Main Previous Cntrl–x to Disconnect
User
Communications Port
Modem Port
Self Test: _____
Front Panel Access: _____
Front Panel Pass-Through: _____
Dial-In Access: _____
Password Mode: _____
Use: _____
Type: _____
Rate: _____
Character Length: _____
Parity: _____
Stop Bits: _____
Use: _____
Type: _____
Rate: _____
Character Length: _____
Parity: _____
Stop Bits: _____
Long Space Disconnect: _____
Figure 2-11. Setting the Password Option
On this screen, set the Password Mode field as
appropriate.
Setting/Changing a Password
For 3160/3164 DSU/CSUs, you have the option of
setting a password for security when receiving a call or
the COM port connection is established. Unless you
specify otherwise, the password is null.
NOTE
To cancel a password operation,
press either the or key
before saving.
Summary of Contents for ACCULINK 316x
Page 4: ...ACCULINK 316x DSU CSU C December 1996 3160 A2 GB22 10 Notices...
Page 23: ...Introduction 1 9 3160 A2 GB22 10 December 1996 Figure 1 6 Auxiliary Backplane...
Page 77: ...Operation 3 35 3160 A2 GB22 10 December 1996 Figure 3 24 Example Channel Allocation...
Page 135: ...A 1 3160 A2 GB22 10 December 1996 Front Panel Menu A...
Page 136: ...ACCULINK 316x DSU CSU A 2 December 1996 3160 A2 GB22 10...
Page 137: ...Front Panel Menu A 3 3160 A2 GB22 10 December 1996...