ACCULINK 316x DSU/CSU
3-10
December 1996
3160-A2-GB22-10
Table 3-4
Data Port LEDs
Name
Color
Meaning
DTR
Green
Monitors the state of interchange circuit CD (CCITT 108/1, /2) – DTE Ready received
from the DTE.
ON :
DTR is being asserted by the DTE.
OFF :
DTR is not being asserted.
TXD
Yellow
Monitors activity on interchange circuit BA (CCITT 103) – Transmitted Data. This is the
data sent from the DTE to the DCE on the DSU/CSU.
ON :
Ones are being received from the DTE.
OFF :
Zeros are being received from the DTE.
CYCLING: Both ones and zeros are being received from the DTE.
RXD
Yellow
Monitors activity on interchange circuit BB (CCITT 104) – Received Data. This is data
sent to the DTE from the DCE on the DSU/CSU.
ON :
Ones are being sent to the DTE.
OFF :
Zeros are being sent to the DTE.
CYCLING: Both ones and zeros are being received from the DTE.
CTS
Yellow
Monitors the state of interchange circuit CB (CCITT 106) – Clear to Send sent to the
DTE.
ON :
CTS is being asserted by the DSU/CSU.
OFF :
CTS is not being asserted.
RTS
Yellow
Monitors the state of interchange circuit CA (CCITT 105) – Request to Send received
from the DTE.
ON :
RTS is being asserted by the DTE.
OFF :
RTS is not being asserted.
Summary of Contents for ACCULINK 316x
Page 4: ...ACCULINK 316x DSU CSU C December 1996 3160 A2 GB22 10 Notices...
Page 23: ...Introduction 1 9 3160 A2 GB22 10 December 1996 Figure 1 6 Auxiliary Backplane...
Page 77: ...Operation 3 35 3160 A2 GB22 10 December 1996 Figure 3 24 Example Channel Allocation...
Page 135: ...A 1 3160 A2 GB22 10 December 1996 Front Panel Menu A...
Page 136: ...ACCULINK 316x DSU CSU A 2 December 1996 3160 A2 GB22 10...
Page 137: ...Front Panel Menu A 3 3160 A2 GB22 10 December 1996...