Maintenance
4-11
3160-A2-GB22-10
December 1996
DTE-initiated Loopbacks
The 316x DSU/CSU complies with the V.54 standard
for initiating local and remote loopbacks. The local
loopback initiates a DTLB, and the remote loopback
initiates a DCLB.
DTLBs and DCLBs can be initiated by the DTEs
attached to ports 1 through 4 per the V.54 standard.
Aborting Loopbacks
The Abort Loopback command stops all loopback tests
or any selected loopback test currently active on the
DSU/CSU.
To abort one or more loopback tests,
1. Press F2 to select Test from the top-level menu
screen.
F1
DSU ESF
Stat
Test
Cnfig
F2
F3
2. From the Test screen, press F2 to select Lpbk.
F1
Test:
Rlpbk Lpbk
Ptrns
F2
F3
3. From the Loopback screen, press F1 to select
Abort.
F1
Loopback:
Abort
LLB
PLB
F2
F3
4. From the Loopback Abort screen, press the
desired function key to abort All or one specific
loopback test. Use the scroll keys, if necessary.
F1
Loopback: Abort
All
LLB
PLB
F2
F3
If you select ALL, LLB, PLB, DLB, or RLB, skip
Step 5.
5. From the Abort screen, press the function key that
corresponds to the port for which you want to
about the test. Use the scroll keys, if necessary.
F1
Abort:
Test Name
Prt1
Prt2
Prt3
F2
F3
When the abortion is complete, the message
Command Complete appears on the Abort
screen.
NOTE
Be careful when selecting a
specific loopback test to abort. If
you mistakenly choose to abort a
loopback test that is not currently
running, a Command Complete
message will still display and the
loopback that is currently active
will still be running. You can use
the TStat branch of the menu to
view the test status to determine if
the abort was successful.
Summary of Contents for ACCULINK 316x
Page 4: ...ACCULINK 316x DSU CSU C December 1996 3160 A2 GB22 10 Notices...
Page 23: ...Introduction 1 9 3160 A2 GB22 10 December 1996 Figure 1 6 Auxiliary Backplane...
Page 77: ...Operation 3 35 3160 A2 GB22 10 December 1996 Figure 3 24 Example Channel Allocation...
Page 135: ...A 1 3160 A2 GB22 10 December 1996 Front Panel Menu A...
Page 136: ...ACCULINK 316x DSU CSU A 2 December 1996 3160 A2 GB22 10...
Page 137: ...Front Panel Menu A 3 3160 A2 GB22 10 December 1996...