ACCULINK 316x DSU/CSU
E-14
December 1996
3160-A2-GB22-10
•
testMonQRSS – Initiates a Monitor QRSS test on
the interface. Supported for the data ports and the
Network T1 interface.
•
testMon511 – Initiates a Monitor 511 test on the
interface. Only supported for the data ports.
•
testSendQRSS – Initiates a Send QRSS test on the
interface. Only supported for the data ports.
•
testSend511 – Initiates a send 511 test on the
interface. Only supported for the data ports.
•
testSendV54Up – Sends a V54 up code to the
remote unit. Only supported for the data ports.
•
testSendV54Down –Sends a V54 down code to the
remote unit. Only supported for the data ports.
•
testSendFT1Up – ends a FT1 up code to the remote
unit. Only supported for the data ports.
•
testSendFT1Down – Sends a FT1 down code to the
remote unit. Only supported for the data ports.
Where these object identifiers are defined as follows:
•
testLoopDTLB – OBJECT IDENTIFIER ::=
[wellKnownTests 2]
•
testMonQRSS – OBJECT IDENTIFIER ::=
[wellKnownTests 3]
•
testMon511 – OBJECT IDENTIFIER ::=
[wellKnownTests 4]
•
testSendQRSS – OBJECT IDENTIFIER ::=
[wellKnownTests 5]
•
testSend511 – OBJECT IDENTIFIER ::=
[wellKnownTests 6]
•
testSendV54Up – OBJECT IDENTIFIER ::=
[wellKnownTests 7]
•
testSendV54Down – OBJECT IDENTIFIER ::=
[wellKnownTests 8]
•
testSendFT1Up – OBJECT IDENTIFIER ::=
[wellKnownTests 9]
•
testSendFT1Down – OBJECT IDENTIFIER ::=
[wellKnownTests 10]
Generic Interface Test Table –
“ifExtnsTestResult” Object
(ifExtnsTestEntry 5)
This object contains the result of the most recently
requested test. Only the following values are supported by
the DSU/CSU.
•
none(1) – No test currently active.
•
inProgress(3) – A test is currently in progress.
•
notSupported(4) – The requested test is not
supported.
•
unAbleToRun(5) – The requested test cannot run
due to the state of the unit.
Generic Interface Test Table –
“ifExtnsTestCode” Object
(ifExtnsTestEntry 6)
This object contains a code which contains more
specific information on the test result. This object is
defined as an INTEGER. Only the following values are
supported by the DSU/CSU.
•
none – No further information is available. Used for
the send pattern/code and loopback tests.
•
inSyncNoBitErrors – A monitor pattern (QRSS or
511) test has synchronized on the pattern and has
not detected any bit errors.
•
inSyncWithBitErrors – A monitor pattern (QRSS or
511) test has synchronized on the pattern and has
detected bit errors.
•
notInSync – A monitor pattern (QRSS or 511) test
has not synchronized on the requested pattern.
Where these object identifiers are defined as follows:
•
wellKnownCodes – OBJECT IDENTIFIER ::=
[ifExtensions 5]
•
none – OBJECT IDENTIFIER ::=
[wellKnownCodes 1]
•
inSyncNoBitErrors – OBJECT IDENTIFIER ::=
[wellKnownCodes 2]
•
inSyncWithBitErrors – OBJECT IDENTIFIER ::=
[wellKnownCodes 3]
•
notInSync – OBJECT IDENTIFIER ::=
[wellKnownCodes 4]
Summary of Contents for ACCULINK 316x
Page 4: ...ACCULINK 316x DSU CSU C December 1996 3160 A2 GB22 10 Notices...
Page 23: ...Introduction 1 9 3160 A2 GB22 10 December 1996 Figure 1 6 Auxiliary Backplane...
Page 77: ...Operation 3 35 3160 A2 GB22 10 December 1996 Figure 3 24 Example Channel Allocation...
Page 135: ...A 1 3160 A2 GB22 10 December 1996 Front Panel Menu A...
Page 136: ...ACCULINK 316x DSU CSU A 2 December 1996 3160 A2 GB22 10...
Page 137: ...Front Panel Menu A 3 3160 A2 GB22 10 December 1996...