Operation
3-9
3160-A2-GB22-10
December 1996
Table 3-3
DSX-1 Drop/Insert Port LEDs
Name
Color
Meaning
SIG
Green
Monitors the signal being received from the DSX-1.
ON :
A recoverable signal is being received from the DSX-1.
OFF :
The signal cannot be recovered from the DSX-1 (a Loss of Signal
condition exists).
OOF
Yellow
Monitors Out Of Frame (OOF) conditions on the received DSX-1 signal.
ON :
At least one OOF was detected on the signal during the sampling
period.
OFF :
No OOFs were detected on the signal during the sampling period.
ALRM
Yellow
Indicates whether an alarm condition exists on the received DSX-1 signal.
ON :
An alarm condition (LOS, LOF, EER, Yellow, AIS) exists on the received
DSX-1 signal. Use the Device Health and Status command to determine
the alarm type.
OFF :
No alarm condition exists on the DSX-1 Interface signal.
PDV
Yellow
Monitors Pulse Density Violations (PDV) on the received DSX-1 signal.
ON :
At least one PDV was detected (and corrected) on the received DSX-1
signal during the sampling period.
OFF :
No PDVs were detected on the received DSX-1 signal during the
sampling period.
BPV
Yellow
Monitors DSX-1 Bipolar Violations (BPV) on the received DSX-1 signal.
ON :
At least one BPV was detected (and corrected) on the received DSX-1
signal during the sampling period.
OFF :
No BPVs were detected on the received DSX-1 signal during the
sampling period.
Summary of Contents for ACCULINK 316x
Page 4: ...ACCULINK 316x DSU CSU C December 1996 3160 A2 GB22 10 Notices...
Page 23: ...Introduction 1 9 3160 A2 GB22 10 December 1996 Figure 1 6 Auxiliary Backplane...
Page 77: ...Operation 3 35 3160 A2 GB22 10 December 1996 Figure 3 24 Example Channel Allocation...
Page 135: ...A 1 3160 A2 GB22 10 December 1996 Front Panel Menu A...
Page 136: ...ACCULINK 316x DSU CSU A 2 December 1996 3160 A2 GB22 10...
Page 137: ...Front Panel Menu A 3 3160 A2 GB22 10 December 1996...