Installation
2-7
3160-A2-GB22-10
December 1996
Installing the Single –
ā
48 Vdc Power Supply
To install the 3160/3164 DSU/CSU using a single
source – 48 Vdc power supply, refer to Figure 2-8 and use
the following procedure.
To install the – 48 Vdc single source power supply,
1. Connect the black and red wires to the – 48 Vdc
return source.
2. Connect the green wire to a suitable earth ground.
3. Connect the orange and blue wires to the –
ā
48 Vdc
input source.
4. Cut the white wire off at the outer insulation.
5. Plug the power connector into the 3160/3164
DSU/CSU.
Figure 2-8. –
ā
48 Vdc Single Source Power Supply Pinouts
Summary of Contents for ACCULINK 316x
Page 4: ...ACCULINK 316x DSU CSU C December 1996 3160 A2 GB22 10 Notices...
Page 23: ...Introduction 1 9 3160 A2 GB22 10 December 1996 Figure 1 6 Auxiliary Backplane...
Page 77: ...Operation 3 35 3160 A2 GB22 10 December 1996 Figure 3 24 Example Channel Allocation...
Page 135: ...A 1 3160 A2 GB22 10 December 1996 Front Panel Menu A...
Page 136: ...ACCULINK 316x DSU CSU A 2 December 1996 3160 A2 GB22 10...
Page 137: ...Front Panel Menu A 3 3160 A2 GB22 10 December 1996...