SNMP MIB Objects
E-9
3160-A2-GB22-10
December 1996
Near End Group –
“dsx1TransmitClockSource” Object
(dsx1ConfigEntry 12)
This object specifies the timing source for the transmit
clock for this T1 interface. This object differs from the
MIB definition in that it is “read-only” (not read/write) for
DSU/CSUs. Only the following values are supported by
the DSU/CSU.
•
loopTiming(1) – The recovered receive clock is
being used as the transmit clock.
•
localTiming(2) – The DSU/CSU’s internal clock is
being used as the transmit clock.
•
ThroughTiming(3) – The recovered receive clock
from another interface (e.g., T1, Port, or External)
is being used as the transmit clock.
Near End Group – “dsx1Fdl” Object
(dsx1ConfigEntry 13)
This object specifies how the Facility Data Link is
being used. Only the following values are supported by
the DSU/CSU. More than one value may be active at a
time.
•
dsx1Ansi-T1-403 (2) – ANSI PRMs are supported
on the Network T1 interface as specified by ANSI
T1.403.
•
dsx1Att-54016(4) – The FDL supports the
requirements specified by AT&T publication
TR54016.
•
dsx1Fdl-none(8) – Indicates that the device does
not use the FDL. This value applies to the DTE
Drop/Insert T1 interface.
Near End Group – The DS1 Current Table
Objects (dsx1CurrentEntry)
The following DS1 current table objects are provided
for the Network T1 interface only. Objects in the table that
are not listed are not supported and will return an error
status if access is attempted.
•
dsx1CurrentIndex – The index that identifies the
T1 interface.
•
dsx1CurrentESs – Errored Seconds for the current
interval.
•
dsx1Current SESs – Severely Errored Seconds for
the current interval.
•
dsx1CurrentUASs – Unavailable Seconds for the
current interval.
•
dsx1CurrentCSSs – Controlled Slip Seconds for the
current interval.
•
dsx1CurrentBESs – Bursty Errored Seconds for the
current interval.
Near End Group – The DS1 Interval Table
Objects (dsx1IntervalEntry)
The following DS1 interval table objects are provided
for the Network T1 interface only. Objects in the table that
are not listed are not supported and will return an error
status if access is attempted.
•
dsx1IntervalIndex – The index that identifies the
T1 interface.
•
dsx1IntervalNumber – The interval number
(1 to 96).
•
dsx1IntervalESs – Errored Seconds for the interval.
•
dsx1Interval SESs – Severely Errored Seconds for
the interval.
•
dsx1IntervalUASs – Unavailable Seconds for the
interval.
•
dsx1IntervalCSSs – Controlled Slip Seconds for the
interval.
•
dsx1Interval BESs – Bursty Errored Seconds for
the interval.
Summary of Contents for ACCULINK 316x
Page 4: ...ACCULINK 316x DSU CSU C December 1996 3160 A2 GB22 10 Notices...
Page 23: ...Introduction 1 9 3160 A2 GB22 10 December 1996 Figure 1 6 Auxiliary Backplane...
Page 77: ...Operation 3 35 3160 A2 GB22 10 December 1996 Figure 3 24 Example Channel Allocation...
Page 135: ...A 1 3160 A2 GB22 10 December 1996 Front Panel Menu A...
Page 136: ...ACCULINK 316x DSU CSU A 2 December 1996 3160 A2 GB22 10...
Page 137: ...Front Panel Menu A 3 3160 A2 GB22 10 December 1996...