E-022-4-E
68
Cont'd.
No.
Item
Description
Type of Setup
Factory Setting
Setting Value
SKdf
Flowrate corr. coeff. (SKdt)
Factory set
6 SKfa
Flowrate corr. coeff. (SKfa)
Factory set
7 SKfb
Flowrate corr. coeff. (SKfb)
Factory set
8 FKt
Flowrate corr. coeff. (FKt)
Factory set
9 FKdt
Flowrate corr. coeff. (FKdt)
Factory set
Density Factor (Density Cal)
60 Dens (Water)
Density at density calibration
Factory set
6 Cal temp
Temp. at density calibration
Factory set
62 Cal temp (Outer)
Temp. at density calibration (outside)
Factory set
63 Cal freq
Freq. at density calibration
Factory set
64
Freq coeff β
Density calibration coeff.β
Factory set
6 Zero factor
Zero factor
Specs. set
Transmitter Information
66 Tag
Tag No.
Specs. set
67 Descriptor
Descriptor
Specs. set
68 Message
Message
Specs. set
69 Date
Date of manufacture
Factory set
70 Device id
Device ID
Factory set
7 Final asmbly num
Serial No.
Factory set
72 Snsr s/n
Sensor serial No.
Factory set
73 Snsr model
Sensor model
Factory set
74 Flange
Flange rating
Factory set
7 Snsr matl
Sensor material
Factory set
76 Hardware rev.
Hardware revision
Factory set
NOTES : No. 62 is an item available only in the ST980.
No. and 9 are items only in the ST980 and EV920.
No. 64 is an item available only in the ST980 and CT940 dedicated to the Mass Flex.
No. 6 and 7 are items available only in the ST980, EV920, and CT940 dedicated to the Mass Flex.
No. 60 through 64 are not included in the EV920.