Prepare the Server for Cold Service
92
Sun Server X4-4 Service Manual • October 2015
Caution -
Data loss. Removing the power cord when the server is in full power mode results
in an immediate shut down of the server. Do not remove the power cord if the server is in full
power mode.
3.
To slide the server out of the rack to the maintenance position, do the following:
Most component service procedures can be performed without removing the server entirely
from the rack. Instead, the server can be slid out of the rack on its support rails to an extended
and locked position called the maintenance position.
a.
At the back of the server, verify that the cables have sufficient length and
clearance to accommodate the distance required to extend the server to the
maintenance position.
The cable management arm (CMA) that is supplied with the server is hinged to facilitate
extending the server to the maintenance position. However, ensure that the cables do not
impede with, or are damaged by, the sliding movement. If necessary, label and remove
cables from the back of the server.
Summary of Contents for Sun Server X4-4
Page 1: ...Part No E38221 05 October 2015 Sun Server X4 4 Service Manual ...
Page 2: ......
Page 10: ...10 Sun Server X4 4 Service Manual October 2015 ...
Page 14: ...14 Sun Server X4 4 Service Manual October 2015 ...
Page 16: ...16 Sun Server X4 4 Service Manual October 2015 ...
Page 64: ...64 Sun Server X4 4 Service Manual October 2015 ...
Page 88: ...88 Sun Server X4 4 Service Manual October 2015 ...
Page 280: ...280 Sun Server X4 4 Service Manual October 2015 ...
Page 284: ...284 Sun Server X4 4 Service Manual October 2015 ...
Page 292: ...292 Sun Server X4 4 Service Manual October 2015 ...