Troubleshoot Hardware Faults
Troubleshooting and Diagnostics
53
Power Supplies (PSUs)
The server power supplies (PSUs) provide the necessary server voltages from the AC power
outlets. If the PSUs are inoperable, unplugged, or disengaged from the internal connectors, the
server cannot power on.
Action
: Check that the AC cables are connected to both PSUs and that the PSUs are operational
(the PSU indicator panel should have a lit green AC OK indicator). If not, ensure that the PSU
is properly installed. A PSU that is not fully engaged with its internal connector does not have
power applied and does not have a lit green AC OK indicator.
Prevention
: When a power supply fails, replace it immediately. To ensure redundancy, the
server has two PSUs. This redundant configuration prevents server downtime, or an unexpected
shutdown, due to a failed PSU. The redundancy allows the server to continue to operate if one
of the PSUs fails. However, when a server is being powered by a single PSU, the redundancy
no longer exists, and the risk for downtime or an unexpected shutdown increases. When
installing a power supply, ensure that it is fully seated and engaged with its connector inside the
drive bay. A properly installed PSU has a lit green AC OK indicator.
Summary of Contents for Sun Server X4-4
Page 1: ...Part No E38221 05 October 2015 Sun Server X4 4 Service Manual ...
Page 2: ......
Page 10: ...10 Sun Server X4 4 Service Manual October 2015 ...
Page 14: ...14 Sun Server X4 4 Service Manual October 2015 ...
Page 16: ...16 Sun Server X4 4 Service Manual October 2015 ...
Page 64: ...64 Sun Server X4 4 Service Manual October 2015 ...
Page 88: ...88 Sun Server X4 4 Service Manual October 2015 ...
Page 280: ...280 Sun Server X4 4 Service Manual October 2015 ...
Page 284: ...284 Sun Server X4 4 Service Manual October 2015 ...
Page 292: ...292 Sun Server X4 4 Service Manual October 2015 ...