Install a Power Supply
Servicing CRU Components
125
Install a Power Supply
This procedure describes how to install a power supply (PSU). When installing a PSU, ensure
that the pawl near the hinge of the latch engages the slot in the sidewall of the PSU bay. The
pawl supplies the necessary leverage to seat the PSU connector with the PSU backplane.
The correct power supply for the Sun Server X4-4 is the
A239C
model.
Caution -
System overheat and shut down. Installing the incorrect model of power supply can
cause the server to over heat. Install only the supported model.
Before You Begin
■
For serviceability considerations, see
“Component Serviceability” on page 66
.
■
For power supply designation information, see
“Component Designations” on page 69
1.
If necessary, remove the failed power supply. See
.
2.
Prepare the server for service. See
.
To perform a cold-service procedure, see
“Prepare the Server for Cold Service” on page 90
.
3.
Ensure that the power supply handle is in the open position.
4.
Align the power supply with the empty power supply bay.
5.
Slide the power supply into the bay until it stops.
6.
To seat the power supply, rotate the release handle upward until it locks in place.
Note -
The pawl at the hinge of the handle must engage the slot at the bottom of the power
supply bay.
Summary of Contents for Sun Server X4-4
Page 1: ...Part No E38221 05 October 2015 Sun Server X4 4 Service Manual ...
Page 2: ......
Page 10: ...10 Sun Server X4 4 Service Manual October 2015 ...
Page 14: ...14 Sun Server X4 4 Service Manual October 2015 ...
Page 16: ...16 Sun Server X4 4 Service Manual October 2015 ...
Page 64: ...64 Sun Server X4 4 Service Manual October 2015 ...
Page 88: ...88 Sun Server X4 4 Service Manual October 2015 ...
Page 280: ...280 Sun Server X4 4 Service Manual October 2015 ...
Page 284: ...284 Sun Server X4 4 Service Manual October 2015 ...
Page 292: ...292 Sun Server X4 4 Service Manual October 2015 ...