Install a Heatsink and CPU (FRU)
184
Sun Server X4-4 Service Manual • October 2015
7.
Remove the tool.
8.
Inspect the CPU to ensure that it sits evenly within the socket.
9.
Close the CPU load plate.
10.
Lower and lock the right side lever, ensuring that the lever is secured under its
retaining clip and that the bend in the lever locks the cover plate.
The right side lever must be closed first.