(Optional) Install the Server Into the Rack
232
Sun Server X4-4 Service Manual • October 2015
The locking is accompanied by an audible click.
6.
Verify that the server is securely mounted in the rack and that the slide-rail locks
are engaged with the mounting brackets.
7.
At the rear of the server, connect the AC power cables to the server power
supplies.
When the power cables are connected to the server, the server powers on to standby power
mode.
8.
Connect any other cables to their connectors or ports on the back of the server.
If the cable management arm (CMA) is in the way, disconnect the left CMA release and swing
the CMA open.
9.
If necessary, reconnect the CMA. See
“(Optional) Install Cable Management
.
Swing the CMA closed and latch it to the left rack rail.
10.
Power on the server. See