Remove a Memory Riser Card
132
Sun Server X4-4 Service Manual • October 2015
■
“Replace a Faulty Memory Riser Card” on page 130
Before You Begin
■
For serviceability considerations, see
“Component Serviceability” on page 66
.
■
For memory riser card designation information, see
“Component Designations” on page 69
■
For reference information, see
“Memory Riser Card and DIMM Reference” on page 141
.
1.
“Prepare the Server for Cold Service” on page 90
2.
To remove the MR card, pull the handles upward to disengage the connector
from the motherboard and carefully lift the memory riser straight up and out of
the server.
The handles act as levers against the sidewalls to extract the card connector from the connector
on the motherboard.