Operation Manual
Section 5
DETAILED SETTINGS
Setting Number of Samples to Average
The number of samples to average is the number of data points used to average data
measured by the Sensor. The average value will be output.
Use the number of samples to average function to ignore sudden variations in measured
values. If the number of samples is increased, however, the response time of the judgement
outputs and linear output will be increased.
Moving to FUN mode and AVE
1.
Set the mode switch to FUN.
2.
Use the LEFT and RIGHT Keys to display
AVE
on the main display.
Selecting Number of Samples to Average
3.
Press the UP or DOWN Key.
The sub-display will flash.
4.
Use the UP and DOWN Keys to select the
number of samples to average.
5.
Press the ENT Key to confirm the selection.
The setting will be registered.
Selection for No. of
samples to average
Response time
1
0.3 ms
2
0.5 ms
4
0.8 ms
8
1.5 ms
16
2.5 ms
32
5 ms
64 (default)
10 ms
128
20 ms
256
40 ms
512
75 ms
1024
150 ms
2048
300 ms
4096
600 ms
Z166-E1-02A.book Page 80 Friday, June 3, 2005 4:18 PM
Summary of Contents for ZX-E -
Page 4: ...2 Preface ZX E Operation Manual Preface ...
Page 8: ...6 Preface Contents ZX E Operation Manual Preface ...
Page 11: ...9 ZX E Operation Manual Preface PREFACE ...
Page 12: ...10 Preface ZX E Operation Manual PREFACE ...
Page 17: ...Section 1 FEATURES 15 ZX E Operation Manual Section 1 FEATURES ZX E Features 16 ...
Page 24: ...22 Section 1 ZX E Features ZX E Operation Manual Section 1 FEATURES ...
Page 62: ...60 Section 3 Adjusting Linearity ZX E Operation Manual Section 3 BASIC OPERATION ...
Page 162: ...160 Appendices Quick Reference for Displays ZX E Operation Manual APPENDICES ...