93
ZX-E
Operation Manual
S
e
c
tion 5
Ch
an
g
in
g
Di
sp
lay
Sc
ales
Section 5
DETAILED SETTINGS
6.
Use the LEFT and RIGHT Keys to display
SCALE
on the main display.
Executing Scaling
7.
Press the UP or DOWN Key.
The sub-display will flash.
8.
Use the UP and DOWN Keys to display ON.
9.
Press the ENT Key to confirm the setting.
The sub-display will show P1SCL.
10.
Set the sensing object at the position where
the display value change is required.
Set the sensing object within the measurement distance. The ENABLE indicator will be lit when the
sensing object is within the measurement distance. Scaling is not possible if the sensing object is
not within the distance.
11.
Press one of the Cursor Keys.
The current measured value will be displayed on the
main display.
The leftmost digit of the sub-display will flash
.
12.
Use the Cursor Keys to set the offset for the
measured value on the sub-display.
The position of the decimal point can be changed using
the next steps.
13.
Press the ENT Key to confirm the settings.
The decimal point will flash.
14.
Use the LEFT and RIGHT Keys to change the
position of the decimal point, if necessary.
Move between digits.
Increment and decre-
ment the numeric value.
Z166-E1-02A.book Page 93 Friday, June 3, 2005 4:18 PM
Summary of Contents for ZX-E -
Page 4: ...2 Preface ZX E Operation Manual Preface ...
Page 8: ...6 Preface Contents ZX E Operation Manual Preface ...
Page 11: ...9 ZX E Operation Manual Preface PREFACE ...
Page 12: ...10 Preface ZX E Operation Manual PREFACE ...
Page 17: ...Section 1 FEATURES 15 ZX E Operation Manual Section 1 FEATURES ZX E Features 16 ...
Page 24: ...22 Section 1 ZX E Features ZX E Operation Manual Section 1 FEATURES ...
Page 62: ...60 Section 3 Adjusting Linearity ZX E Operation Manual Section 3 BASIC OPERATION ...
Page 162: ...160 Appendices Quick Reference for Displays ZX E Operation Manual APPENDICES ...