Section 4
MAIN APPLICATIONS AND SETTING METHODS
Setting Measurement Timing
The hold function is used for height measurement. The minimum value (bottom) during
the sampling period is held.
When the timing signal cannot be input from the device, set a self-down trigger.
The following settings are required when the reference sample height is displayed using the scaling
function:
Measurement trigger: Self-up trigger
Hold condition:
Peak hold
Refer to
Section 5 Detailed Settings
for details on settings.
Using Hold Functions, p. 81
Measured value
Sampling
Self-trigger level
The bottom value is held.