145
ZX-E
Operation Manual
Ap
p
e
n
d
ices
Spe
c
if
ic
a
tions
a
n
d
Dime
ns
io
ns
APPENDICES
ZX-CAL2 Calculating Unit
Applicable Amplifier Units
ZX Series
Current consumption
12 mA max. (supplied from the Smart Sensor Amplifier Unit)
Ambient temperature
Operating: 0 to 50
°
C, Storage:
−
15 to 60
°
C (with no icing or condensation)
Ambient humidity
Operating and storage: 35% to 85% (with no condensation)
Connection method
Connector
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min
Insulation resistance
100 M
Ω
(at 500 VDC)
Vibration resistance (destructive)
10 to 150 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions
Shock resistance (destructive)
300 m/s
2
3 times each in six directions (up/down, left/right, forward/backward)
Materials
Display: Acrylic, Case: ABS resin
Weight (packed state)
Approx. 50 g
(Unit: mm)