Mutual Interference
When using multiple Sensor Heads, separate each Sensor Head by the minimum dis-
tances shown in the following diagram.
The distance between Sensor Heads can be further reduced when the Sensor Heads are side by
side if the mutual interference prevention function is used.
Performing Calculations, p. 116
(Unit: mm)
Model
A
B
Mutual Interference Prevention Function
Used
Not used
ZX-EDR5T
5
3.1
20
ZX-ED01T
10
5.4
50
ZX-ED02T
20
8
50
ZX-EM02T
20
10
50
ZX-EM07MT
100
30
150
ZX-EV04T
80
14
50
ZX-EM02HT
20
12
50
•