![background image](http://html.mh-extra.com/html/omron/zx-e/zx-e_operation-manual_1633397139.webp)
137
ZX-E
Operation Manual
Ap
p
e
n
d
ices
Er
ro
r M
e
s
s
a
g
e
s
a
nd Count
e
rme
a
s
ur
e
s
APPENDICES
Error Messages and Countermeasures
This section outlines the error messages displayed on the main display and the countermea-
sures for those messages.
Display
Error
Countermeasure
Pages
E-CHL
There are two Sensors but only one
Amplifier Unit connected.
• If two Amplifier Units have been connected, turn OFF the
power supply and check that the Amplifier and
Calculating Units are connected correctly.
• If only one Amplifier Unit is being used, connect another
Amplifier Unit temporarily and turn OFF the two-sensor
operation, or initialize the settings data.
p. 25
p. 34
p. 116
p. 133
E-DAT
Two-sensor operation communica-
tions data error
• Change the mode for the CH1 Amplifier Unit to RUN.
• Turn OFF the power supply and check that the Amplifier
and Calculating Units are connected correctly.
Replace the Amplifier Unit or the Calculating Unit if the
above countermeasures do not solve the problem.
p. 25
p. 34
E-EEP
EEPROM data error
Hold down the ENT Key for three seconds or longer. Once
the data has been cleared, cycle the power supply.
Replace the Amplifier Unit if the above countermeasure
does not solve the problem.
p. 25
E-HED
The Sensor Head is disconnected.
Turn OFF the power supply, check that the Sensor Head is
connected correctly, and then turn ON the power supply.
Replace the Sensor Head if the above countermeasure
does not solve the problem.
p. 30
E-SEN
The Sensor Head is disconnected
or other factors are causing it to
malfunction.
Turn OFF the power supply, check the connection for the
Sensor Head, and then turn ON the power supply again.
Replace the Sensor Head if the above countermeasure
does not solve the problem.
p. 30
E-SHT
One or all of the judgement outputs
are short-circuited.
Turn OFF the power supply, check that the HIGH, PASS,
and LOW output lines are not short-circuited, then turn ON
the power supply again.
p. 38
E-THK
The thickness T is not set for thick-
ness operation.
Set an appropriate thickness T.
p. 74
ERRLH
An attempt was made to set a
numeric value larger than the HIGH
threshold value to the LOW thresh-
old value.
Input correct threshold values.
p. 97
HIGH threshold
−
LOW threshold
<
hysteresis width
ERRHL
An attempt was made to set a
numeric value smaller than the
LOW threshold value to the HIGH
threshold value.
Input correct threshold values.
p. 97
HIGH threshold
−
LOW threshold
<
hysteresis width
ERROV
The set numeric value is too large.
Input an appropriate numeric value.
p. 50
HIGH threshold
−
LOW threshold
<
hysteresis width
ERRTB
Linearity adjustment failed.
Confirm the selected material and sensing object position,
then perform adjustment again.
p. 54
ERRUD
The set numeric value is too small.
Input an appropriate numeric value.
p. 50
Z166-E1-02A.book Page 137 Friday, June 3, 2005 4:18 PM
Summary of Contents for ZX-E -
Page 4: ...2 Preface ZX E Operation Manual Preface ...
Page 8: ...6 Preface Contents ZX E Operation Manual Preface ...
Page 11: ...9 ZX E Operation Manual Preface PREFACE ...
Page 12: ...10 Preface ZX E Operation Manual PREFACE ...
Page 17: ...Section 1 FEATURES 15 ZX E Operation Manual Section 1 FEATURES ZX E Features 16 ...
Page 24: ...22 Section 1 ZX E Features ZX E Operation Manual Section 1 FEATURES ...
Page 62: ...60 Section 3 Adjusting Linearity ZX E Operation Manual Section 3 BASIC OPERATION ...
Page 162: ...160 Appendices Quick Reference for Displays ZX E Operation Manual APPENDICES ...