Section 6
AUXILIARY FUNCTIONS
Initializing Settings Data
This function resets all settings to their default values.
Linearity adjustments, however, are not initialized using this function. To initialize linearity adjustment
data, perform initialization in linearity adjustment mode.
Initializing Adjustment Settings, p. 59
Function
Default Value
No. of samples to average
64
Hysteresis width
The default differs depending on the connected Sensor Head.
•
ZX-EDR5T: 0.0003
•
ZX-ED01T: 0.0004
•
ZX-ED02T: 0.0008
•
ZX-EM02T: 0.0008
•
ZX-EM07MT: 0.003
•
ZX-EV04T: 0.0016
•
ZX-EM02HT: 0.0008
Hold
OFF
Timer
OFF
Special functions
CLOSE
Scaling
OFF
Monitor focus
At 0 mm: 4 (mA)
At rated measurement distance: 20 (mA)
Linear output correction
No correction
Display reverse
OFF
ECO display
OFF
No. of display digits
5 digits (all)
Non-measurement settings
KEEP
Zero reset memory
ON
HIGH threshold
The default differs depending on the connected Sensor Head.
•
ZX-EM07MT:
59.999 (mm)
•
Other Sensor Heads: 5.9999 (mm)
LOW threshold
The default differs depending on the connected Sensor Head.
•
ZX-EM07MT:
−
19.999 (mm)
•
Other Sensor Heads:
−
1.9999 (mm)
Z166-E1-02A.book Page 133 Friday, June 3, 2005 4:18 PM
Summary of Contents for ZX-E -
Page 4: ...2 Preface ZX E Operation Manual Preface ...
Page 8: ...6 Preface Contents ZX E Operation Manual Preface ...
Page 11: ...9 ZX E Operation Manual Preface PREFACE ...
Page 12: ...10 Preface ZX E Operation Manual PREFACE ...
Page 17: ...Section 1 FEATURES 15 ZX E Operation Manual Section 1 FEATURES ZX E Features 16 ...
Page 24: ...22 Section 1 ZX E Features ZX E Operation Manual Section 1 FEATURES ...
Page 62: ...60 Section 3 Adjusting Linearity ZX E Operation Manual Section 3 BASIC OPERATION ...
Page 162: ...160 Appendices Quick Reference for Displays ZX E Operation Manual APPENDICES ...