Section 4
MAIN APPLICATIONS AND SETTING METHODS
Setting Measurement Timing
The hold function is used to detect the bottom deadpoint.
To ignore bounding when measuring during press operation, specify a time delay from
the timing signal to when sampling starts.
When the timing signal cannot be input from the device, set a self-down trigger.
Refer to
Section 5 Detailed Settings
for details on settings.
Using Hold Functions,
p. 81
Measured value
Self-trigger level
The bottom value is held.
Timing input
Delay
time
Sampling
period