1.
Put the press machine in inching mode and
lower the stripper (or top mold) to the bottom
deadpoint.
2.
Adjust the position of the Sensor Head so that
this position is at about half of the measure-
ment distance.
The measured value will be displayed on the
Amplifier Unit. Refer to this display while
adjusting the Sensor Head.
Stripper or top mold
Bottom mold
1/2 the
measurement
distance