Section 6
AUXILIARY FUNCTIONS
Setting Thicknesses
7.
Use the LEFT and RIGHT Keys to display
THICK on the main display.
8.
Press the UP or DOWN Key.
The leftmost digit of the sub-display will flash.
9.
Set the thickness of the standard sensing
object.
Enter the actual dimensions of the reference object.
The position of the decimal point can be changed using
the next steps.
10.
Press the ENT Key to confirm the setting.
The numeric values will be confirmed and the decimal
point will flash.
11.
Use the LEFT and RIGHT Keys to move the
decimal point.
12.
Press the ENT Key to confirm the position of
the decimal point.
The scaling values (A and B) are registered for both
Amplifier Units.
Countermeasures for Setting Errors
If the display shows E-THK, the standard sensing object
is outside the measurement distance. (The ENABLE indi-
cator will not be lit.)
Adjust the position of the reference object until the
ENABLE indicator is lit on both Amplifier Units and exe-
cute the measurement again.
Move between digits.
Increment and decre-
ment the numeric value.
Thickness
Z166-E1-02A.book Page 119 Friday, June 3, 2005 4:18 PM
Summary of Contents for ZX-E -
Page 4: ...2 Preface ZX E Operation Manual Preface ...
Page 8: ...6 Preface Contents ZX E Operation Manual Preface ...
Page 11: ...9 ZX E Operation Manual Preface PREFACE ...
Page 12: ...10 Preface ZX E Operation Manual PREFACE ...
Page 17: ...Section 1 FEATURES 15 ZX E Operation Manual Section 1 FEATURES ZX E Features 16 ...
Page 24: ...22 Section 1 ZX E Features ZX E Operation Manual Section 1 FEATURES ...
Page 62: ...60 Section 3 Adjusting Linearity ZX E Operation Manual Section 3 BASIC OPERATION ...
Page 162: ...160 Appendices Quick Reference for Displays ZX E Operation Manual APPENDICES ...