![background image](http://html.mh-extra.com/html/omron/zx-e/zx-e_operation-manual_1633397143.webp)
141
ZX-E
Operation Manual
Ap
p
e
n
d
ices
Spe
c
if
ic
a
tions
a
n
d
Dime
ns
io
ns
APPENDICES
Notes:
1. The response speed of the linear output is calculated as the measurement period x (No. of samples to
average s 1).
The response speed of the judgement outputs is calculated as the measurement period x (No. of samples
to average s 1).
2. The output can be switched between current output and voltage output using a switch on the bottom of the
Amplifier Unit.
3. Setting is possible via the monitor focus function.
4. A Calculating Unit is required.
Functions
Measured value
display
Present value dis-
play
Output value dis-
play
Set value display
Resolution display
ENABLE indicator
Zero reset indica-
tor
Power ON indica-
tor
Judgement indica-
tor
ECO mode
Display reverse
Display digit limit
Zero reset
Zero reset memory
Previous value compari-
son
Initialization
Linearity initialization
Teaching
Direct threshold value
setting
Hysteresis width setting
Scaling
Linearity adjustment
Monitor focus
Linear output correc-
tion
Peak hold
Bottom hold
Sample hold
Peak-to-peak hold
Average hold
Delay hold
Delay time setting
ON-delay timer
OFF-delay timer
One-shot timer
Timing inputs
Self-up trigger
Self-down trigger
(A-B) calculations
(See note 4.)
(A+B) calculations
(See note 4.)
Thickness calculation
(See note 4.)
Mutual interference
prevention
(See note 4.)
Key lock
Clamp value setting
Indications
Judgement indicators: HIGH (orange), PASS (green), LOW (yellow), 7-segment main display
(red), 7-segment sub-display (yellow), power ON (green), zero reset (green), enable (green)
Voltage influence
(including Sensor)
0.5% F.S. of linear output value at
±
20% of power supply voltage
Power supply
voltage
12 to 24 VDC
±
10%, Ripple (p-p): 10% max.
Power consumption 3.4 W max. (Sensor connected)
(Power supply voltage: 24 V, Current consumption: 140 mA max.)
Ambient
temperature
Operating and storage: 0 to 50
°
C (with no icing or condensation)
Ambient humidity
Operating and storage: 35% to 85% (with no condensation)
Insulation
resistance
20 M
Ω
min. at 500 VDC
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min
Vibration resistance
(destructive)
10 to 150 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions
Shock resistance
(destructive)
300 m/s
2
3 times each in six directions (up/down, left/right, forward/backward)
Connection method Prewired (standard cable length: 2 m)
Weight (packed
state)
Approx. 350 g
Materials
Case: PBT (polybutylene terephthalate), Cover: Polycarbonate
Accessories
Instruction sheet
ZX-EDA11
ZX-EDA41
Z166-E1-02A.book Page 141 Friday, June 3, 2005 4:18 PM
Summary of Contents for ZX-E -
Page 4: ...2 Preface ZX E Operation Manual Preface ...
Page 8: ...6 Preface Contents ZX E Operation Manual Preface ...
Page 11: ...9 ZX E Operation Manual Preface PREFACE ...
Page 12: ...10 Preface ZX E Operation Manual PREFACE ...
Page 17: ...Section 1 FEATURES 15 ZX E Operation Manual Section 1 FEATURES ZX E Features 16 ...
Page 24: ...22 Section 1 ZX E Features ZX E Operation Manual Section 1 FEATURES ...
Page 62: ...60 Section 3 Adjusting Linearity ZX E Operation Manual Section 3 BASIC OPERATION ...
Page 162: ...160 Appendices Quick Reference for Displays ZX E Operation Manual APPENDICES ...