background image

 

 

L54 Tinted Lens – Manual 

 

WAM454TintedA  

Standby AB – standbygroup.se 

L54 Tinted Lens 

Thank you for choosing a product from Standby. 

Technical Data 

Lens 

Polycarbonate 

Housing 

Aluminium (black) 

Color 

Blue 

Diodes 

6 high power LED 

Cable 

Single: 0.84 m (160 mm + 680 mm) + 2 m driver cable 

Power 

10-30 V DC 

Ambient temperature 

-40ºC to +85ºC 

Power consumption 

0.8 A peak at 13.8 V 
0.4 A peak at 27.6 V 

Size 

Lamp: 85 x 36 x 15 mm 
Driver (single): 80 x 14.3 x 18.6 mm 
Driver (double): 80 x 14 x 27 mm

Approvals 

Light: ECE R65 (E5) 
EMC: ECE R10 (E5) 

Included 

Single:  
1 x L54 Lamp  
1 x driver D13s 
 
Double: 
2 x L54 Lamp  
1 x driver D13d 

Synchronizing 

Up to 10 units (lamps and driver) 

 

Factory Settings 

Flash pattern 

Sync mode 

Double 

Simultaneous 

To change the flash pattern setting, see Flash Pattern. To change the sync mode setting, see Sync Mode. 

 

 

Summary of Contents for L54

Page 1: ...perature 40ºC to 85ºC Power consumption 0 8 A peak at 13 8 V 0 4 A peak at 27 6 V Size Lamp 85 x 36 x 15 mm Driver single 80 x 14 3 x 18 6 mm Driver double 80 x 14 x 27 mm Approvals Light ECE R65 E5 EMC ECE R10 E5 Included Single 1 x L54 Lamp 1 x driver D13s Double 2 x L54 Lamp 1 x driver D13d Synchronizing Up to 10 units lamps and driver Factory Settings Flash pattern Sync mode Double Simultaneou...

Page 2: ... The factory setting of flash pattern is Double When in configuration mode the number of blank flashes lamp off in the flash sequence show the current flash pattern setting see table Blank flashes per flash sequence Flash pattern Flash control 1 Double Built in 2 Triple Built in 3 First generation Double Built in 4 First generation Triple Built in 5 Steady burn 1 External 6 Steady burn 2 External ...

Page 3: ...ed incorrectly you must restart from step 2 6 Count the number of blank flashes lamp off per flash sequence to find out the current flash pattern setting 7 Temporarily connect the white wire to ground to change to the next version of flash pattern Each time the white wire is temporarily connected to ground the next version of flash pattern is selected 8 To change the sync mode setting see Sync Mod...

Page 4: ...eans that the lamps are out of sync The factory setting of sync mode When in configuration mode the number of bright flashes per flash sequence show the current sync mode setting see table Bright flashes per flash sequence Sync mode 1 Simultaneous 2 Alternate Setting the Sync Mode WARNING Risk of eye damage Do not look into the beam at close range 1 If already in configuration mode go to step 6 2 ...

Page 5: ...tly you must restart from step 2 6 Count the number of bright flashes per flash sequence to find out the current sync mode setting 7 Temporarily connect the blue wire to ground to change to the next version of sync mode Each time the blue wire is temporarily connected to ground the next version of sync mode is selected 8 To change the flash pattern setting see Flash Pattern To reset to factory set...

Page 6: ...lash pattern Double Sync mode Simultaneous Reset to Factory Settings WARNING Risk of eye damage Do not look into the beam at close range Note All current settings are reset to the default settings 1 If already in configuration mode go to step 6 2 If the lamp is connected to the power supply disconnect it 3 Connect the red wire to 10 30 V DC via a 5 A fuse 4 Connect the black wire to ground ...

Page 7: ...ed for at least 2 sec The lamp enters configuration mode and a flash sequence indicating the current settings starts Note If this step is performed incorrectly you must restart from step 2 6 Connect the BLUE and the WHITE wire to ground and let them stay connected for at least 2 seconds 7 The reset is confirmed with a bright steady light for 2 3 seconds ...

Page 8: ...ply Good and suitable ground Red Power supply Lamp on off 10 30 V DC via a 5 A fuse Sourcing output of an I O unit or via a switch White Synchronizing the flashing of two or more lamps Sync cable of the other lamp Blue Not used Table 2 Connections if flash pattern Steady burn 1 is selected Wire Functions Connect to Black Power supply Good and suitable ground Red Power supply 10 30 V DC via a 5 A f...

Page 9: ...rn Steady burn 2 is selected Wire Functions Connect to Black Power supply Good and suitable ground Red Power supply Lamp on off 10 30 V DC via a 5 A fuse Sourcing output of an I O unit or external flasher White Synchronizing the flashing of two or more lamps Sync cable of the other lamp Blue Not used ...

Page 10: ...L54 Tinted Lens Manual WAM454TintedA 10 Standby AB standbygroup se Installation CAUTION When using a pressure washer keep a minimum distance of 40 cm ...

Reviews: