11
Wiring Controller Power and Ground
Section 2-3
2-3
Wiring Controller Power and Ground
Wire the power supply and the ground to the top terminal block, and
tighten the screws to a torque of between 0.5 and 0.6 N•m. After wir-
ing, check to make sure that the wiring is correct.
2-3-1
Crimp Terminals and Cables
The terminal block uses M3 terminal screws. Use appropriate crimp
terminals for M3 screws, as shown below.
2-3-2
Protective Conductor (Earth) Wiring
Note
1.
Use an appropriate ground. An insufficient ground can affect
V530-C300E operation or result in damage to V530-C300E com-
ponents.
2.
To avoid damage to the equipment, do not share the protective
conductor wiring with any other devices nor wire the protective
conductor terminal to the girder. Be sure to wire the protective
conductor of the equipment independently.
3.
Keep the ground line as short as possible.
Terminal
Maker
Model No.
Wire size
J.S.T. Mfg. Co., Ltd.
V1.25-N3A
1.31 to
1.65 mm
2
(AWG16
to
AWG15)
J.S.T. Mfg. Co., Ltd.
V1.25-MS3
Forked
6.2 mm max.
Round
6.2 mm max.
24VDC
PWR
RUN
ERR
RS-232C
SCANNER
MONITOR
CONSOLE
2D CODE READER
V530-C300
1
2
3
4
5
6
O
N
TRIG
Class I (with protective
conductor terminal)