60
SET (Setting) Mode
Section 5-1
3.
Select the code size. It is possible to set up to two (1 or 2) code
sizes. If the reading codes are all the same size, set this size as
code size 1, and set code size 2 to “None.”
(10
10 to 26
26; Default setting: Code size 1 = 10
10, code
size 2 = None)
4.
Turn ON the free finder length setting if there is more than one
size of code being read and the difference is large enough to in-
terfere with reading. If the free finder length setting is turned ON,
an code of the same size or larger than the finder length set in (5)
will be read. (Default setting: OFF)
5.
Input the length of the finder pattern (L-shape) in pixel units.
(50 to 480; Default setting: 150)
This setting can be made automatically using the teaching func-
tion, so whenever resetting the reading conditions, always use the
teaching function first. page 56
When Free Finder Length (4) is set to ON, set the minimum length
of the reading codes as the value of the length of the finder pat-
tern.
6.
Select the background cut level required when searching for find-
er patterns (L-shapes). when reading for white symbol printed on
black base, such as with direct marking, it is recommended that
this level is set to middle or strong. (Weak/Middle/Strong; Default
setting: Weak)
7.
Select the timeout time for decoding one reading. (Setting range:
200 to 2,000 ms; default setting: 1,000 ms)
Normal Procedure
1,2,3...
1.
Select Read DM (Normal).
2. Image Analysis
0. Image Adjust (DM)
1. Read DM (Normal)
Select the Reading Parameters.