101
SET (Setting) Mode
Section 5-1
2.
The average densities of the black and white cells will be dis-
played along with the contrast (density ratio). The contrast will be
displayed between 0.00 and 1.00. The larger the numeric value
the higher the contrast.
3.
Specified white cell region.
4.
Specified black cell region.
Note
Analysis is not possible on a through image.
Procedure
1,2,3...
1.
Select 2.Image Analysis.
2.
Select Contrast (Region).
3.
Move the cross cursor with the Up/Down/Left/Right Keys and
press the ENT Key when the cursor is at upper left corner of the
white region. Press the SHIFT Key together with the above keys
to move the cursor faster
4.
Move the cross cursor with the Up/Down/Left/Right Keys and
press the ENT Key when the cursor is at lower right corner of the
white region.
5.
Specify the black region using the same procedure as was used
for the white region.
The black pixel, white pixel, and contrast values will be displayed
on the screen.
6.
Press the ENT Key to return to step (2).
1. Read DM (Normal)
2. Image Analysis
0. Image Adjust
Analyse input image.
Display Pixel Value
Contrast (Region)
Hardware Check
Image Magnifier
Measure Length
Contrast (Line Bright)