150
Regular Inspections
Section 7
To maintain the V530-C300E in the best condition, perform the fol-
lowing regularly.
• Lightly wipe off dirt with a soft cloth.
• Clean the lens and indicators with a cloth for a lens or air brush.
Note
1.
Turn OFF the power and take safety precautions before conduct-
ing inspections.
2.
Do not use thinners or benzene.
Inspection items
Details
Required tools
Power Supply
The voltage measured at the power supply
terminals on the terminal block must be
24 VDC (+10%, –15%).
Circuit Tester
Ambient Temperature
The operating ambient temperature inside
the cabinet must be between 0 to +38
C.
Thermometer
Ambient Humidity
The operating ambient humidity inside the
cabinet must be between 35 to +85%.
Hygrometer
Installation
Each cable connector must be correctly
inserted and locked.
Phillips screw driver