SET (Setting) Mode
Section 5-1
It is possible to view and, if necessary, change the parameter set-
ting in Reading Settings (Manual).
page 73
If reading is not performed correctly, the teaching function will stay
ON. To turn the teaching function OFF, select Reading Settings
(Manual) from the screen shown in step 2, and press the ENT
Key. The teaching function will be turned OFF by entering the
Reading Settings (Manual) window.
The reading conditions can be set manually. If parameters have been
set using the teaching function, those parameters can be viewed or
changed, if necessary, from this menu.
Note
Items 2 and 3 above can be set using the teaching function.
OK 6568ms
ABCDE12345
GrayEdgeVal: 18 (11~26), Rev: OFF
The parameters obtained are displayed. These
parameters are used as settings.
Only the read data (ABCDE12345 in this example)
is output to RS-232C.
RUN
Freeze (3)
1. Read QR (Normal)
Reading Settings (Manual)
Symbol Color
:
Black
▼
Right&Left Reverse
:
OFF
▼
Gray Edge Value
: [32]
Gray Edge Value Retry
:
OFF
▼
Timeout
: [500]ms
A
B
C
E